The MISU Screening Unit sources its power from the carrier units
hydraulic system.
The key criteria when selecting and matching a MISU screen to a
carrier unit ultimately depends on two variables:
- The carrier units weight - so the bucket and carrier unit are
balanced and does not to exceed the static tipping load of the carrier
- The carrier units hydraulic horsepower
When an order for a MISU screen occurs all specifications and variables
are calculated out according to the specific carrrier unit.
|
|
excavator units |
Excavator machines need to be piped for 'Bi-Directional
Flow' to run the screen in two directions or clockwise or anticlockwise
directions.
The pressure in the circuit must be limited to
no more than 200 Bar (2,900 p.s.i) and hydraulic oil flow set to
the manufacturers specification's. Refer
to the appropriate model section. |
| |
loader units |
Loader units run off the 'Four-in-one' system,
or the '3rd hydraulic function' The pressure in the circuit must be limited to
no more than 200 Bar and hydraulic oil flow set to the manufacturers
specification's. Refer to the appropriate
model section.
|
| |
skid steer units |
Skid Steer units run off the attachment hydraulic
flow system.
The pressure in the circuit must be limited to
no more than 200 Bar and hydraulic oil flow set to the manufacturers
specification's. Refer to the appropriate model section.
Ideally the weight of a carrier skidsteer machine
should be close to 3 ton for balance purposes. |
| |
Top
|
Street Address: 6 Sanyo Drive, Wodonga 3690, Victoria,
Australia
Mailing Address: PO Box 107, Wodonga, 3689, Victoria,
Australia
Phone: (+61) 02 6024 3155 Fax: (+61) 02 6024 3065 Email: sales@misu.com.au